PROTECT YOUR DNA WITH QUANTUM TECHNOLOGY
Orgo-Life the new way to the future Advertising by AdpathwayAutomated threshold-based artificial intelligence volumetry reflects overall tumor burden but is not interchangeable with anatomically guided expert delineation in non-small cell lung cancer, according to a method-comparison study evaluating positron emission tomography and computed tomography scans. Researchers assessed whole-body tumor metrics at baseline and throughout treatment, revealing that automated volumetric measurements diverge substantially from manual reference segmentations once therapy commences. Although automated tools provide observer-independent quantification, their level of agreement with manual evaluations proves limited at the individual-patient level, indicating that artificial intelligence algorithms should currently serve as complementary clinical instruments rather than outright replacements for experienced imaging specialists.
Whole-body tumor burden has emerged as a promising imaging biomarker for evaluating disease extent and monitoring therapeutic response on fluorine-18 fluorodeoxyglucose positron emission tomography combined with computed tomography, known as [¹⁸F]FDG-PET/CT. Automated algorithms offer the potential to deliver standardized, observer-independent volumetric metrics across clinical workflows. However, automated threshold-based segmentations and manual expert segmentations rely on inherently different contouring principles, leaving the practical concordance between these two measurement strategies unresolved across different treatment phases.
To evaluate this concordance, investigators conducted a retrospective single-center study examining [¹⁸F]FDG-PET/CT scans from 118 patients with histologically confirmed non-small cell lung cancer. The full dataset encompassed 396 imaging examinations, consisting of 118 baseline scans acquired prior to therapy and 278 follow-up examinations performed during the course of treatment. Manual whole-body tumor delineations performed by expert observers were systematically compared against automated volumetric metrics generated by CE-marked software.
The research team employed a rigorous statistical framework to benchmark the performance of the automated software against the manual reference standard. Agreement was evaluated using Lin’s concordance correlation coefficient alongside Bland–Altman analysis to capture systematic bias and limits of agreement across scales. The investigators also determined coverage probability within predefined relative margins of plus or minus 20 percent of manual measurements, evaluated concordance regarding the detection of measurable tumor burden, and tracked agreement in relative volume change from baseline. To account for repeated imaging sessions within individual subjects, all follow-up examinations were incorporated into a secondary statistical model.
At baseline, concordance between automated and manual volumetry appeared moderate to good, although the estimates demonstrated considerable statistical variability. Lin’s concordance correlation coefficient reached 0.94 with a 95 percent confidence interval of 0.74 to 0.95 for TMTVSUV4, whereas TMTV41% achieved a concordance correlation coefficient of 0.81 with an interval of 0.35 to 0.86. Despite these relatively high baseline coefficients, both metrics displayed wide and asymmetric confidence intervals. Furthermore, the coverage probability within plus or minus 20 percent of the manual reference volume reached only 26.3 percent for both automated metrics prior to treatment initiation, demonstrating notable baseline measurement discrepancies.
Concordance deteriorated substantially during treatment, marking a pronounced divergence in the primary follow-up analysis. At the first follow-up examination, the concordance correlation coefficient dropped to 0.74 for TMTVSUV4 and plummeted to 0.40 for TMTV41%, while secondary analysis across all 278 follow-up scans yielded coefficients of 0.59 and 0.40, respectively. Systematic directional biases became evident on the ratio scale: at the first follow-up, TMTV41% overestimated manual volume by 46 percent, yielding a geometric mean ratio of 1.46 with a 95 percent confidence interval of 1.19 to 1.79. Conversely, TMTVSUV4 underestimated manual volume by 63 percent, producing a geometric mean ratio of 0.37 with a confidence interval of 0.29 to 0.48. Coverage probabilities within plus or minus 20 percent fell to 11.1 percent for TMTV41% and 13.7 percent for TMTVSUV4.
A critical clinical discrepancy emerged regarding the detection of persistent disease during post-baseline monitoring. Across the 278 follow-up examinations, TMTVSUV4 returned a tumor volume of zero in 28 instances where expert readers identified positive, measurable disease. Evaluating relative changes from baseline revealed poor tracking, with concordance correlation coefficients of 0.08 for TMTV41% and 0.44 for TMTVSUV4. When tumor volume changes were categorized into exploratory response brackets defined by a plus or minus 30 percent threshold, inter-method agreement was only fair, showing Cohen’s kappa values of 0.32 for TMTV41% and 0.35 for TMTVSUV4. These findings underscore that automated PET volumetry cannot safely substitute for expert manual assessment when tracking non-small cell lung cancer therapy.
Subject of Research: Agreement between automated AI volumetry and manual tumor delineation in PET/CT for lung cancer
Article Title: Agreement between AI-based automated and expert-defined manual whole-body tumor volume assessment in [¹⁸F]FDG-PET/CT of NSCLC patients
Article References: Ebner, R., Heimer, M. M., Zöller, E., Herr, F. L., Dascalescu, C. A., Schnitzer, M. L., Rübenthaler, J., Fabritius, M. P., Sabel, B. O., Sheikh, G. T., Klimek, K., Tufman, A., Ingrisch, M., Ricke, J., Shiyam Sundar, L. K., Werner, R. A., & Cyran, C. C. (2026). Agreement between AI-based automated and expert-defined manual whole-body tumor volume assessment in [¹⁸F]FDG-PET/CT of NSCLC patients. BMC Medical Imaging. https://doi.org/10.1186/s12880-026-03039-y
Image Credits: AI Generated
DOI: 10.1186/s12880-026-03039-y
Keywords: non-small cell lung cancer, [18F]FDG-PET/CT, automated tumor volumetry, total metabolic tumor volume, manual tumor segmentation, artificial intelligence, biomarker quantification, treatment response monitoring, Lin's concordance correlation coefficient, Bland-Altman analysis, TMTV41%, TMTVSUV4, CE-marked software, medical imaging, coverage probability, Cohen's kappa, baseline PET/CT, tumor burden assessment


5 hours ago
19




















English (US) ·
French (CA) ·