Report highlights gaps in training, size-up in Wyo. firefighter's fall

1 hour ago 6

PROTECT YOUR DNA WITH QUANTUM TECHNOLOGY

Orgo-Life the new way to the future

  Advertising by Adpathway

NIOSH cites fall protection, risk management culture and SOP training in a Jackson Hole firefighter’s fall during a fire

November 16, 2026 11:52 AM • 

Report highlights gaps in training, size-up in Wyo. firefighter's fall.jpg

The firefighter fell from between the two dormers shown in the photo onto a concrete sidewalk. He landed near the staged RIT, whose members immediately provided care.

Photo|NIOSH, fire department

JACKSON HOLE, Wyo. — On May 25, 2026, a Jackson Hole firefighter was seriously injured after falling from a steep roof during vertical ventilation. The Truck 16 crew had been assigned to ventilate the Side Delta portion of the structure. The NIOSH report stated that after completing the first hole near the peak, the crew repositioned the aerial platform between two dormers. The firefighter unhooked his safety tether from the platform and stepped onto the roof to start the next cut.

The firefighter lost his footing, slipped from one dormer to the other and fell about 20 feet to the ground. Mayday calls went out from both the aerial turntable and the platform. He suffered fractures to his lower leg and heel and was transported for treatment.

Key investigation findings

The firefighter left the platform without fall protection. NIOSH lists the fall from the aerial platform as the first contributing factor. The firefighter unhooked his tether to reach the roof, so nothing arrested the fall once he lost his footing on the steep pitch.

Size-up and risk assessment came up short. NIOSH identified the initial scene size-up and risk assessment as a contributing factor and recommends a risk-benefit analysis before firefighters are committed to vertical ventilation.

Truck company training and evaluation did not match the task. NIOSH found a need for training and evaluation based on rank and skill across the combination department’s career and volunteer personnel. The department has since begun building a truck company task book to confirm that personnel can perform the tasks a truck company may be assigned. That includes vertical ventilation on residential and commercial structures.

Culture and SOPs shaped the decision. NIOSH cited department culture and risk management as a contributing factor and recommends balancing the life safety mission with proactive risk management. It also cited SOPs and SOGs, which only help if crews are trained on them and review them routinely. The department has started a full SOP review.

Fire department activation was delayed. NIOSH listed delayed activation of the fire department response as a contributing factor. The longer a fire burns before the department is alerted, the more damage and loss it causes, and the more likely crews are to face a roof they must work. The summary does not say how long the delay was.

Recommended department actions

Make sure firefighters use and maintain fall prevention devices on every aerial platform. The tether only works if it stays attached until the firefighter is anchored to something else. Build a transfer procedure into your aerial operations and inspect the equipment on a set schedule.

Complete a size-up and risk assessment before committing anyone to a roof. NIOSH wants the first-arriving resource to inform a risk-benefit analysis before vertical ventilation begins. The department’s own lessons echo this: plan the apparatus placement, request additional resources early and dedicate a staged RIT company.

Evaluate personnel by rank and skill, and match specialty crews to their tasks. NIOSH recommends a professional development program with routine evaluation for all combination department personnel. If your department assigns people to a truck company, have them demonstrate the competencies that company requires.

Promote a risk-aware culture and keep SOPs current. Train on your SOPs and SOGs and review them routinely. When initial companies establish command, the incident commander should update dispatch with the correct address so crews not yet on scene can pull pre-incident plans.

Consider requiring monitored detection in commercial occupancies. NIOSH suggests this regardless of when a building was constructed. Earlier activation shortens the time a fire has to breach a roof before crews arrive.

FireRescue1 articles referenced in the report:

Training discussion questions

  1. Your crew is on an aerial platform beside a steep, dormered roof, and the next cut requires stepping off. What has to be true before anyone unhooks and who decides?
  2. How does your department decide when vertical ventilation is worth the risk and who makes that call when the first-arriving company is a truck?
  3. If you run a combination department, how do you confirm that a volunteer and a career firefighter assigned to the same truck have the same demonstrated skills?

Utica Fire & Rescue created its own EMS service after New Chapel EMS was ousted from the district, launching operations Nov. 16 with about 50 trained volunteers, including 15 EMTs and seven paramedics

November 15, 2026 08:00 AM

All six residents evacuated safely from the Multnomah County house, as Oregon’s lithium-ion battery fires have climbed an average of 19% annually since 2020, with e-bikes and scooters the most common cause

November 15, 2026 12:00 PM

The Congressional Fire Services Institute named the Virginia Beach Fire Department the 2027 Sarbanes Award winner for a program focused on firefighter health, safety and readiness

November 16, 2026 07:39 AM

 · 

The Ottumwa Fire Department wants to add six full-time personnel to run a 24-hour ambulance, but the city faces a $500,000 budget shortfall

November 16, 2026 09:19 AM

Backed by Motorola Solutions Foundation and other NFFF partners, 67 recipients will receive financial assistance to pursue higher education in 2026-2027 academic year

November 02, 2026 02:45 PM

Bill Carey is the associate editor for FireRescue1.com and EMS1.com. A former Maryland volunteer firefighter, sergeant, and lieutenant, Bill has written for several fire service publications and platforms. His work on firefighter behavioral health garnered a 2014 Neal Award nomination. His ongoing research and writings about line-of-duty death data is frequently cited in articles, presentations, and trainings. Have a news tip? He can be reached at [email protected].