Orgo-Life the new way to the future Advertising by AdpathwayIn posterior single-tooth implant rehabilitations, the use of anatomic healing abutments significantly shortens the duration of the clinical digital-impression procedure while substantially increasing the subsequent laboratory computer-aided design time, according to findings from a prospective, non-randomized controlled pilot study published in the Digital Dentistry Journal. The investigation, conducted by researchers at Hannover Medical School, demonstrated that while anatomic healing abutments streamlined intraoral data capture by permitting direct scanning of the healing component in place, the resulting digital models required extensive manual adjustments during crown design. Consequently, the clinical procedural savings achieved at the dental chair were outweighed in absolute duration by additional processing demands placed on the dental technician, reflecting a pronounced redistribution of procedural workload rather than an overall improvement in total workflow efficiency across the restorative continuum.
Achieving predictable functional and esthetic outcomes in dental implantology depends heavily on the careful preservation and conditioning of peri-implant soft tissues. In conventional digital implant workflows, standard cylindrical healing abutments support tissue maturation during initial osseointegration, but capturing the developed emergence profile requires a multi-step sequence. Clinicians must temporarily remove the healing abutment, perform an immediate optical scan of the collapsing mucosal cuff, seat and torque an independent scan body to record implant position, perform a second digital scan, and finally replace and retighten the original healing cap. This iterative mechanical exchange introduces clinical handling steps that prolong chairside intervals and can potentially induce mechanical disturbance to healing peri-implant tissues prior to definitive prosthetic delivery.
To simplify these restorative sequences, prefabricated anatomic healing abutments were developed to combine soft-tissue contouring and optical data acquisition within a solitary transgingival component. Featuring an integrated scan body and a standardized anatomical emergence profile based on original manufacturer geometry, these abutments can be captured directly with an intraoral scanner without requiring intermediate disconnections or component substitutions. Although anatomic healing abutments share conceptual elements with the established One Abutment One Time protocol by minimizing early tissue disruption during impression procedures, they do not fully replicate that methodology because the healing components must still be disconnected and replaced when delivering the final definitive crown. Prior to the present investigation, empirical evidence quantifying the precise temporal differences between anatomic and conventional workflows in both clinical and technical phases remained scarce.
To address this clinical knowledge gap, the research team designed a prospective controlled trial evaluating two specific phase-dependent intervals: the clinical digital-impression procedure time and the laboratory-based computer-aided crown design time. Following ethical approval from the Ethics Committee of Hannover Medical School under approval number 11666_BO_K_2024 and trial registration in the German Clinical Trials Register, twenty adult patients requiring single-tooth implant restorations were consecutively enrolled. The participant cohort comprised ten women and ten men aged between 38 and 65 years, presenting a mean age of 51 years. Eligible individuals demonstrated American Society of Anesthesiologists physical status classifications of I or II and possessed sufficient native alveolar bone volume to receive posterior implants without concurrent guided bone regeneration procedures.
Patient recruitment and treatment allocation followed a pragmatic, non-randomized protocol across consecutive clinical intake periods. Over an initial one-month window, consecutive eligible candidates were informed about the anatomic healing abutment approach; ten patients consenting to this protocol formed the test cohort. Following completion of this group, ten subsequent consecutive patients meeting identical eligibility criteria received conventional restorative management using standard healing abutments and separate scan bodies, forming the control cohort. All twenty participants received Straumann BLX implants placed exclusively in posterior quadrants, specifically seven maxillary and thirteen mandibular sites, with no anterior locations treated. Baseline evaluations showed that the test group had a mean age of 53.2 years across three premolar and seven molar sites, whereas the conventional group demonstrated a mean age of 48.9 years across one premolar and nine molar sites.
Standardization across the clinical and technical phases was maintained by having a single clinician with more than ten years of experience perform all surgical and scanning steps, while a single dental technician possessing over ten years of digital dental laboratory experience completed all restorative designs. Surgical guide planning was conducted using coDiagnostiX software, and intraoral digital impressions were recorded using a Trios 4 optical scanner. For the test cohort, Straumann Anatomic Healing Abutments XC featuring standardized 3-millimeter heights were placed at 14 Newton-centimeters of tightening torque. In nine of the ten test cases, prefabricated abutments were utilized without modification; in one patient, minor chairside contour adjustment was performed prior to scanning to refine tissue adaptation, though this pre-procedural adjustment was completed before the start of the timed impression protocol.
Clinical impression timing was restricted specifically to the predefined scanning interval using a digital stopwatch. In the conventional cohort, timing initiated immediately prior to unscrewing the healing abutment, encompassed emergence-profile scanning, scan-body seating, scan-body optical acquisition, scan-body removal, and healing-abutment reseating, terminating once the healing abutment was fully retightened. For this conventional group, the total clinical digital-impression procedure time averaged 102.69 ± 3.98 seconds, with a 95% confidence interval of 99.84 to 105.54 seconds. Within this sequence, the cumulative mechanical exchange of components occupied 22.79 ± 4.18 seconds, optical capture of the emergence profile required 66.70 ± 6.43 seconds, and optical scanning of the scan body required 13.20 ± 1.99 seconds.
In contrast, the clinical impression protocol for the anatomic healing abutment group required an average of 64.30 ± 4.97 seconds, with a 95% confidence interval spanning 60.75 to 67.85 seconds. Because the anatomic component remained seated throughout, timing began at the initiation of intraoral optical scanning and stopped upon achieving a clinically acceptable digital impression, completely eliminating component-exchange and scan-body manipulation steps. Statistical testing confirmed that the data satisfied assumptions of normality via the Shapiro-Wilk test, and an independent-samples t-test established that the clinical digital-impression duration in the anatomic group was significantly shorter than that observed in the conventional group, demonstrating an average reduction of 38.39 seconds (p < 0.001) and leading to the rejection of the study’s first null hypothesis.
Conversely, evaluation of the subsequent laboratory design phase demonstrated an inverted temporal relationship. Digital restoration design was conducted using DentalCAD 3.2 Elefsina software based on digital dental models imported into Dental System 2024. For the conventional workflow, where the physiological emergence profile had been recorded directly from intraoral tissue collapse and scan bodies, laboratory technicians primarily performed margin definition and standard crown modeling, completing designs in a mean time of 1196.29 ± 63.79 seconds. In the anatomic group, the prefabricated transgingival contours of the healing abutment did not consistently match the final ideal prosthetic emergence profile, requiring technicians to perform repeated manual refinements, cervical contour corrections, soft-tissue adaptations, and alignment checks that extended the mean design duration to 1617.10 ± 60.72 seconds.
Because the laboratory design time measurements deviated from a normal distribution, between-group differences were evaluated using the non-parametric Mann-Whitney U test. This analysis confirmed that the 420.81-second increase in laboratory design time—representing an added technical commitment of approximately 7.01 minutes per restoration—was statistically significant (p < 0.001), resulting in the rejection of the second null hypothesis. The authors emphasized that rejection of both hypotheses reflects distinct, opposing phase-specific time shifts rather than cumulative procedural superiority. The modest chairside reduction of roughly 38 seconds was substantially overshadowed by the additional seven minutes of computer-aided engineering required per restoration, shifting the operational burden from the dental operatory into the dental laboratory.
Regarding clinical safety and postoperative progress, all twenty enrolled patients completed the assigned protocols without subject dropout, missing data points, or technical complications. Visual descriptive inspections of peri-implant mucosal tissues during abutment manipulation revealed no acute adverse events requiring secondary intervention, such as active bleeding, uncontrolled swelling, infectious episodes, or wound dehiscence. However, the investigators explicitly noted that soft-tissue observations were purely incidental and qualitative, lacking validation via standardized periodontal probing depths, bleeding indices, esthetic scoring criteria, biochemical fluid analyses, or patient-reported outcome measures, meaning no definitive inferences regarding biological superiority or mucosal health can be established from the dataset.
The researchers underscored several critical methodological constraints that necessitate cautious interpretation of these findings. First, the investigation was structured as a small pilot trial involving twenty patients recruited via a non-randomized, pragmatic process without formal statistical power calculations or allocation concealment, meaning self-selection and residual confounding cannot be ruled out. Second, the clinical protocol measured only an isolated scanning window rather than the comprehensive chairside appointment or full patient visit, and excluding the pre-procedural contour modification required in one anatomic case may have slightly favored that group. Additionally, the execution of all clinical and technical procedures by single experienced operators using manual stopwatch timing limits generalizability across diverse clinical settings and less experienced practitioners.
Finally, because all treated sites were restricted to posterior premolar and molar regions, these findings cannot be extrapolated to anterior aesthetic zones where emergence profile requirements, mucosal scalloping, and visibility constraints present distinct clinical challenges. Furthermore, the investigation did not evaluate definitive restoration parameters such as marginal fit, internal adaptation, occlusal accuracy, or delivery-time adjustments, nor did it include a formal cost-effectiveness analysis to assess whether minor chairside time savings justify elevated laboratory expenses. The authors concluded that while anatomic healing abutments successfully eliminate intraoral component handling during impression procedures, larger randomized trials incorporating comprehensive automated time tracking, multi-center practitioner cohorts, and formal economic evaluations are needed before broad workflow efficiencies can be confirmed.
Subject of Research: Digital implant workflow procedural time comparison between anatomic and conventional healing abutments
Article Title: Clinical digital-impression procedure time and laboratory design time using anatomic healing abutments: A prospective pilot study
Article References: Alevizakos, V., Platte, A.-C., Schiller, M., & von See, C. (2027). Clinical digital-impression procedure time and laboratory design time using anatomic healing abutments: A prospective pilot study. Digital Dentistry Journal, 5(1), Article 100130. https://doi.org/10.1016/j.ddj.2026.100130
Image Credits: AI Generated
DOI: 10.1016/j.ddj.2026.100130
Keywords: digital dentistry, implantology, anatomic healing abutments, intraoral scanning, computer-aided design, clinical workflow efficiency, laboratory design time, emergence profile, dental implants, Straumann BLX, scan bodies, prosthetic restoration, pilot study, dental technology, chairside procedure time, posterior implant restoration, restorative dentistry